9 Series (30 Products)
Junction Box for Heat Tracing / De-Ice - Wall Mounted Series TEF1058
- High degree of protection, IP66/67, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel Type Label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 2 heating cables
Junction Box for Heat Tracing / De-Ice - Pipe Mounted Series TEF1058
- High degree of protection, IP66/67, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel Type Label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 4 heating cables
Capillary Tube Thermostat – Pipe Mounted Series TEF1058
- High degree of protection IP66/67 is standard, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel type label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 4 heating cables
Junction Box for Heat Tracing - Wall Mounted Series TEF1058
- High degree of protection, IP66/67, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel Type Label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 2 heating cables
Junction Box for Heat Tracing - Pipe Mounted Series TEF1058
- High degree of protection, IP66/67, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel Type Label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 2 heating cables
Electronic Thermostat - Wall Mounted / Pipe Mounted Series TEF1058
- High degree of protection IP66/67 is standard, IP68 can be delivered upon request
- Drainage flange in box prevents penetration of water
- Manufactured in acid proof stainless steel (AISI 316L)
- Tailor made size and performance is possible
- Stainless steel type label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- Low lifetime maintenance cost
Capillary Tube Thermostat Series TEF1058
- High degree of protection IP66/67 is standard, IP67 without breather
- Manufactured in acid proof stainless steel (AISI 316L)
- Stainless steel type label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- High operational reliability
- Low lifetime maintenance cost
- Recommended for up to 4 heating cables
Ambient Sensing Electronic Thermostat Series TEF1058
- High ingress protection IP66/67 is standard, IP68 can be delivered upon request
- Drainage flange in box prevents penetration of water
- Manufactured in acid proof stainless steel (AISI 316L)
- Tailor made size and performance is possible
- Stainless steel type label spot welded to the cover
- Several earthing alternatives
- Maximum strength and corrosion resistance
- Low lifetime maintenance cost